Installation—Mechanical
UV-SVN03F-EN 21
4. Remove shipping bracket from the lower rear corners
of the unit to separate the unit from the skid. Access to
the screws holding the bracket to the skid is obtained
inside the unit.
5. Rotate the fan wheels manually
. The wheels should
move freely and be in proper alignment. Visually
inspect the fan area for obstructions or shipping
damage.
6. Remove all applicable knockouts for coil
piping and
electrical connections.
Location Considerations
Selecting the appropriate location for installing a unit is
very important. The following factors should be
considered:
1. Floor design must have sufficient structure to
withstand the weight of the unit while allowing for
openings in the floor for a return air duct, electrical and
piping supply lines fed through the floor. Refer to
“Dimensions and Weights,” p. 11 for unit weights.
2. Wall space design should allow the unit to be mounted
to
the wall securely. The wall surface behind the unit
should be smooth and level. Wall and floor moldings
should be removed prior to installation. A wall slightly
out of level may cause problems with unconditioned
air leaking into the room. Remove any object
projecting more then 1/8 in. (0.3175 cm) from the wall
surface.
Note: Ad
ditional gasket or furr strips may be installed
to accommodate for an uneven wall.
3. There are two removable knock
-outs in the rear of the
unit, on either end, for piping and electrical supply
lines. A pipe chase is located in the upper back portion
of the unit for crossover piping. The outside air
opening is located in the lower back of the unit and the
path to the wallbox on the outside wall should be
unobstructed.
4. The physical layout of the
room should accommodate
any accessories ordered with the unit. Conditioned air
is distributed through the grille on top of the unit and
returned through the return air grille on the bottom of
the unit. Avoid placing any objects that may obstruct
either grille or interfere with airflow.
5. Internal access to the unit is pr
ovided by the removable
front panel. Sufficient space should be allowed to lift
the panel for maintenance purposes.
6. Ensure the floor surface is level.
Note: The unit leveling legs can be adjusted to
accommodate slight out-of-level installation
surfaces.
Unit Mounting
Note: All wall intake boxes should be installed prior to
mounting the unit ventilator. Refer to p. 20 for wall
box installation instructions.
The 1/2 in. mounting or anchoring holes are located on the
back of the unit on each end (see Figure 11, p. 22).
Note: All mounting fasteners are to be provided by the
installer.
WARNING
Heavy Object!
Floor structure must be strong enough to support the
weight of the unit. Consult the structural plans, and
have a structural engineer ensure the floor can
withstand the weight of the unit. Inadequate structural
support could result in unit falling.
Failure to follow recommendations could result in
death or serious injury.