SAFETY WARNING
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-
conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment
by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and
on the tags, stickers, and labels that are attached to the equipment.
Packaged Rooftop Air Conditioners
Voyager
Heat Pump
12½ – 20 Ton, 60/50 Hz
Installation, Operation,
and Maintenance
Model Numbers
WS*150-240
RT-SVX33E-EN
May 2014
Seitenansicht 0
1 2 3 4 5 6 ... 43 44

Inhaltsverzeichnis

Seite 1 - Installation, Operation

SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

Seite 2 - Environmental Concerns!

General Information10 RT-SVX33E-ENstream or return air stream, the air velocity entering the smoke detector unit must be between 500 and 4000 feet pe

Seite 3 - Overview of Manual

RT-SVX33E-EN 11Unit DimensionsFigure 1. Typical installation clearances for single & multiple unit applicationsWITHOUT ECONOMIZER5' 8"

Seite 4 - Table of Contents

Unit Dimensions12 RT-SVX33E-ENFigure 2. Heat pump models - 12½ - 15 tons* All dimensions are in inches/millimeters.DOWNFLOW CONDENSATEDRAIN CONN 1&qu

Seite 5 - Model Number Description

Unit DimensionsRT-SVX33E-EN 13 Figure 4. Heat pump models - 12½ - 15 tons* All dimensions are in inches/millimeters.Figure 5. Heat pump models - 12½ -

Seite 6 - Model Number Notes

Unit Dimensions14 RT-SVX33E-ENFigure 7. Heat pump models - 20 tons* All dimensions are in inches/millimeters.DOWNFLOW CONDENSATEDRAIN CONN 1" (2

Seite 7 - General Information

Unit DimensionsRT-SVX33E-EN 15 Figure 9. Heat pump models - 20 tons* All dimensions are in inches/millimeters.Figure 10. Heat pump models - 20 tons* D

Seite 8 - Functions

Unit Dimensions16 RT-SVX33E-ENFigure 12. Downflow & horizontal condensate locationsTable 1. Unit dimensionsTonsCondensate Drain SizeCondensate Dr

Seite 9

RT-SVX33E-EN 17Unit WeightsRiggingRefer to Figure 14 and Table 3 for typical unit operating weights rigging before proceeding.1. Remove the shipping c

Seite 10 - Zone Sensors

18 RT-SVX33E-ENInstallationFoundationNotes:• For units with optional Condensate Overflow Switch (COF), the switch will not work properly if unit is n

Seite 11 - Unit Dimensions

InstallationRT-SVX33E-EN 19 Electric Heat Requirements• Verify that the power supply complies with the electric heater specifications on the unit and

Seite 12

© 2014 Trane All rights reserved RT-SVX33E-ENWarnings, Cautions and NoticesWarnings, Cautions and Notices. Note that warnings, cautions and notices

Seite 13

Installation20 RT-SVX33E-ENNote: If the unit is not equipped with an optional factory installed nonfused disconnect switch or circuit breaker, a fiel

Seite 14

InstallationRT-SVX33E-EN 21 1. Use copper conductors unless otherwise specified.2. Ensure that the AC control wiring between the controls and the unit

Seite 15

Installation22 RT-SVX33E-ENFigure 18. Typical field wiring diagrams for optional controls (ReliaTel™ only)BAYSENS119*BAYSENS075*BAYSENS075*BAYSENS075

Seite 16

InstallationRT-SVX33E-EN 23 Space Temperature AveragingSpace temperature averaging is accomplished by wiring a number of remote sensors in a series/pa

Seite 17 - Unit Weights

Installation24 RT-SVX33E-ENVoltage ImbalanceThree phase electrical power to the unit must meet stringent requirements for the unit to operate properl

Seite 18 - Installation

InstallationRT-SVX33E-EN 25 Compressor Crankcase HeatersEach compressor is equipped with a crankcase heater. The proper operation of the crankcase hea

Seite 19 - Field Installed Power Wiring

26 RT-SVX33E-ENFactory-Mounted Unit OptionsCircuit Breaker (FIYUCB) & Unit Disconnect (FIYUDC)Important: All phases of this installation must com

Seite 20 - 20 RT-SVX33E-EN

Factory-Mounted Unit OptionsRT-SVX33E-EN 27 Powered/Unpowered Convenience OutletPowered Convenience Outlet Powered Option (FIYCOPO)When the powered co

Seite 21 - Component Failure!

Factory-Mounted Unit Options28 RT-SVX33E-ENUnpowered Convenience Outlet Unpowered Option (FIYCOUP)1. When the unpowered convenience outlet option is

Seite 22 - ASYSTAT669*

Factory-Mounted Unit OptionsRT-SVX33E-EN 29 4. Slide one 2” piece of the vinyl tubing provided onto the short smoke detector inlet tube which protrude

Seite 23 - Space Temperature Averaging

Warnings, Cautions and NoticesRT-SVX33E-EN 3 Overview of ManualNote: One copy of this document ships inside the control panel of each unit and is cust

Seite 24 - Voltage Imbalance

Factory-Mounted Unit Options30 RT-SVX33E-ENIn order for the return air smoke detector to properly sense smoke in the return air stream, the air veloc

Seite 25 - Compressors Failure!

RT-SVX33E-EN 31Pre-StartTest ModesThere are three methods in which the “Test” mode can be cycled at LTB-Test 1 and LTB-Test 2.1. Step Test Mode - This

Seite 26 - Factory-Mounted Unit Options

Pre-Start32 RT-SVX33E-ENVerifying Proper Air Flow (Units with Belt Drive Indoor Fan)Much of the systems performance and reliability is closely associ

Seite 27 - Convenience Outlet

RT-SVX33E-EN 33Start UpEconomizer Start-UpUsing the Service Test Guide in Table 7, p. 31, momentarily jump across the Test 1 & Test 2 terminals on

Seite 28 - B - Powered

Start Up34 RT-SVX33E-ENHeating Start-Up1. Clamp an amp meter around one of 1st stage heater power wires at the heater contactor.2. Using the Service

Seite 29 - Airflow & Sampling

RT-SVX33E-EN 35MaintenanceMake sure all personnel are standing clear of the unit before proceeding. The system components will start when the power is

Seite 30

Maintenance36 RT-SVX33E-ENFiltersInspect the return air filters. Clean or replace them if necessary. Refer to the unit Service Facts for filter infor

Seite 31 - Pre-Start

MaintenanceRT-SVX33E-EN 37 Do not heat the detergent-and-water solution above 150°F. Hot liquids sprayed on the exterior of the coil will raise the co

Seite 32 - Return Air Smoke Detector

38 RT-SVX33E-ENTroubleshootingReliaTel ControlsThe RTRM has the ability to provide the service personnel with some unit diagnostics and system status

Seite 33 - Start Up

TroubleshootingRT-SVX33E-EN 39 Below is the complete listing of failure indication causes.System Failure Check the voltage between terminals 6 and 9 o

Seite 34 - Final System Setup

4 RT-SVX33E-ENTable of ContentsModel Number Description . . . . . . . . . . . . . . . 5General Information . . . . . . . . . . . . . . . . . . . .

Seite 35 - Maintenance

Troubleshooting40 RT-SVX33E-ENZone Temperature Sensor (ZTS) Service IndicatorThe ZSM SERVICE LED is a generic indicator, that will signal the closing

Seite 36 - Coil Cleaning

TroubleshootingRT-SVX33E-EN 41 Note: Measurements should be made from LED common (ZSM terminal 6 to respective LED terminal). Refer to the Zone Sensor

Seite 37 - Hazardous Pressures!

Troubleshooting42 RT-SVX33E-ENUnit Economizer Control (ECA) TroubleshootingTable 13. Verify economizer status by economizer actuator (ECA) LED indica

Seite 38 - Troubleshooting

RT-SVX33E-EN 43Wiring DiagramsNote: Wiring diagrams can be accessed via e-Library by entering the diagram number in the literature order number search

Seite 39 - Lockouts

The manufacturer optimizes the performance of homes and buildings around the world. A business of IngersollRand, the leader in creating and sustaining

Seite 40 - Method 3

RT-SVX33E-EN 5Digit 1 — Unit TypeW = Packaged Cooling, Electric HeatDigit 2 — EfficiencyS = Standard EfficiencyDigit 3 — Airflow ConfigurationD=Downfl

Seite 41 - Sensor Test

6 RT-SVX33E-ENModel Number DescriptionH = Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensingand Condensate Drain PanOverflow SwitchDigi

Seite 42

RT-SVX33E-EN 7General InformationUnit InspectionAs soon as the unit arrives at the job site:• Verify that the nameplate data matches the data on the s

Seite 43 - Wiring Diagrams

General Information8 RT-SVX33E-ENtemperature, and/or humidity conditions depending on the application. The stages of capacity control for these units

Seite 44 - Warranty

General InformationRT-SVX33E-EN 9 The system will continue to operate regardless of the status of the filter switch.Please note that on units equipped